General Specifications | |
Cabinet Type | Upright |
Capacity | 858L / 30.29 cu ft |
Internal Size(W*D*H) | 877*696*1378mm 34.52*27.40*54.25in |
External Size(W*D*H) | 1217*1025*2005mm 47.91*40.35*78.93in |
Package Size(W*D*H) | 1330*1155*2176mm 52.36*45.47*85.66in |
NW/GW(Kgs) | 390/431 |
Certification | ETL |
Performance | |
Temperature Range | -40 ~ -86 °C |
Ambient Temperature | 16 – 32°C |
Climate Class | N |
Cooling Performance | -86 °C |
Controller | Microprocessor |
Display | Touch screen |
Refrigeration | |
Compressor | 1pc (SECOP brand) |
Cooling Method | Direct cooling |
Defrost Mode | Manual |
Refrigerant | Mixture gas |
Insulation Thickness(mm) | 130 |
Construction | |
External Material | High quality steel plates with spraying |
Inner Material | Galvanized steel sheet |
Shelves | 3(stainless steel) |
Door Lock with Key | Yes |
External Lock | Yes |
Access Port | 3pcs. Ø 25 mm |
Casters | 4+(2 leveling feet) |
Data Logging/Interval/Recording Time | USB/Record every 1 minute / 365 days |
Backup Battery | Yes |
Alarm | |
Temperature | High/Low temperature, High ambient temperature |
Electrical | Power failure |
System | Sensor error, Built-in datalogger USB failure, Main board communication error, Condenser cooling failure, |
Door ajar, Sapmles out of date, System failure | |
Electrical | |
Power Supply(V/HZ) | 220/60 |
Rated Current(A) | 12 |
Options Accessory | |
System | Chart recorder, CO2 backup system, Printer. Remote alarm contact |
Temperature Range(℃) | 2~8 |
---|---|
Controller | Microprocessor |
Display | LED |
Power Supply(V/Hz) | 220-240/50 115/60 |
Power(W) | 135 75 |
Electrical Current(A) | 1.03 /1.11 |
Capacity(L/Cu.Ft) | 105L / 3.70 cu ft |
Net/Gross Weight(approx) | 42/52(kg) |
Interior Dimensions(W*D*H) | 410*650*420mm 16.14*25.59*16.53in |
Exterior Dimensions(W*D*H) | 510*885*560mm 20.07*34.84*22.04in |
Container load (20’/40’/40’H) | 48/96/144 |
Sentinel Next PRO Probe for ultra-low freezers and liquid nitrogen chambers. Used in tissue and blood storage, pharmaceutical and other healthcare applications
Probe Length & Diameter Stainless probe: 25mm, Ø 4mm (1”, Ø 0.16”)
Cable Length: 304cm (10ft)
Measurement Range: -30°C to +150°C (-22°F to +302°F)
Accuracy: ±0.2°C (±0.4°F) at 25°C (77°F)
Response Time (to reach 90%) In water, with stirring: <10sec
Display Resolution: 0.1°C (0.1°F)
Uses the cell phone network to monitor across all your facilities thereby eliminating IT security concerns, network performance issues and support commitment from IT. Automates monitoring of temperature, humidity, differential pressure, CO2 and more to meet compliance standards with 24/7 real-time continuous monitoring. Alerting system uses emails, text messages and APPs for notifications. The system meets 21 CFR 11 requirements, are ideal for monitoring of refrigerators, freezers and ultralow freezers.
[maxbutton id="1" url="https://www.aegisfridge.com/contact/" ]Sentinel Next Ultra Low Temperature Probe for ultra-low freezers and liquid nitrogen chambers. Used in tissue and blood storage, pharmaceutical and other healthcare applications
Probe Length & Diameter Stainless probe: 25mm, Ø 4mm (1”, Ø 0.16”)
Cable Length: 183cm (6ft)
Measurement Range: -200°C to +150°C (-328°F to +302°F)
Accuracy: ±0.2°C (±0.4°F) at 25°C (77°F)
Response Time: (to reach 90%) In water, with stirring: <10sec
Display Resolution: 0.1°C (0.1°F)
Optional DI (Digital Input): dry contact available
RTD Probe for ultra-low freezers and liquid nitrogen chambers. Used in tissue and blood storage, pharmaceutical and other healthcare applications
[maxbutton id="1" ]
Sentinel Next RTD probe with Dry Contact for ultra-low freezers and liquid nitrogen chambers. Used in tissue and blood storage, pharmaceutical and other healthcare applications
Probe Length & Diameter Stainless probe: 25mm, Ø 4mm (1”, Ø 0.16”)
Cable Length: 183cm (6ft)
Measurement Range: -200°C to +150°C (-328°F to +302°F)
Accuracy: ±0.2°C (±0.4°F) at 25°C (77°F)
Response Time: (to reach 90%) In water, with stirring: <10sec
Display Resolution: 0.1°C (0.1°F)
Optional DI (Digital Input): dry contact available
Door Contact
Circuit type Open loop
Operation gap ½”(13mm)
Color: White
Terminals: Screw-type
Mounting Tabs: Yes
Case: High-impact ABS plastic
Contacts: Deactivated rhodium on gold under-plating
Contact rating: 0.1A@100VDC (max) 1.0A@10VDC (max) 10W (max)
Temperature: -15°~160°F (-25°~70°C)
Switch cycles: 50 Million (0.1mA@5VDC)
Switch Dimensions: 21/2′′x9/16′′x1/2′′ (63.5x14x13mm)
Magnet Dimensions: 21/2′′x1/2′′x1/2′′ (63.5x13x13mm)
Magnet Type: Ferrite
Aegis provides affordable, low power Wi-Fi sensor network solutions that make a ubiquitous sensing world come alive and a full line of controlled temperature cabinets. Laboratory, Pharmacy and Chromatography refrigerators and freezers which are designed to meet the dimensional and temperature requirements of the scientific community.
OH: 513 204 5837
PA: 215-281-9180
support@aegisfridge.com