General Specifications | |
Capacity | 1.8L / 0.0635 cu ft |
Temp. Range | -40 – -75°C |
Ambient Temperature | 16 – 32°C |
Cooling | Direct cooling |
Display | Digital display |
Climate Class | N |
Internal Size(WDH) | 5.98*5.23*3.42in 152*133*87mm |
External Size(WDH) | 9.64*11.10*19.52in 245*282*496mm |
Package Size(WDH) | 12.40*15.15*20.86in 315*385*530mm |
NW/GW(Kgs) | Dec-14 |
Alarm System | High/low temperature , Sensor fault , Powe outage |
Power Supply(V/HZ) | DC24V, AC100V-240V/50 |
Rated Power(W) | 60 |
Input Power(W) | 80 |
Current Consumption(KWh/24h) | 2.24 |
Rated Current(A) | 0.46 |
External Material | SPCC steel with powder coating |
Inner Material | EVA |
External Lock | yes |
Stainless Temperature Probe with Platinum RTD sensor
Datalogging thermometer that meets 21 CFR 11 requirements, are ideal for monitoring temperatures in refrigerators, freezers, water baths, heating blocks, and incubators. High-accuracy thermometer has a temperature range of -50 to 70°C and resolution of 0.01°C and maintains an accuracy of ±0.25°C across the entire temperature range.
The countertop blanket warmers for labor and delivery rooms, ICU and NICU
• Glass window to view contents inside
• Energy-efficient coated glass door
• Standard lights, UV lamps, with circulation fan
• Digital temperature limiter
Temperature Range(℃) | 2~8 |
---|---|
Controller | Microprocessor |
Display | LED |
Power Supply(V/Hz) | 220-240/50 115/60 |
Power(W) | 135 75 |
Electrical Current(A) | 1.03 /1.11 |
Capacity(L/Cu.Ft) | 105L / 3.70 cu ft |
Net/Gross Weight(approx) | 42/52(kg) |
Interior Dimensions(W*D*H) | 410*650*420mm 16.14*25.59*16.53in |
Exterior Dimensions(W*D*H) | 510*885*560mm 20.07*34.84*22.04in |
Container load (20’/40’/40’H) | 48/96/144 |
![]() |
Air Cooling, Auto defrost Better cabinet temperature uniformity, Auto defrost |
![]() |
Adjustable Shelves The shelves are adjustable to any height and satify different requirements. |
![]() |
Five Alarm Functions High/low temperature, Power failure, Door ajar, Sensor error , Low battery |
Key Features
The countertop incubator for research and laboratories
• The double door structure with high quality glass and excellent sealing
• Energy-efficient coated glass door
• Standard lights, UV lamps, with circulation fan.
• Digital temperature limiter
Sentinel Next RTD probe with Dry Contact for ultra-low freezers and liquid nitrogen chambers. Used in tissue and blood storage, pharmaceutical and other healthcare applications
Probe Length & Diameter Stainless probe: 25mm, Ø 4mm (1”, Ø 0.16”)
Cable Length: 183cm (6ft)
Measurement Range: -200°C to +150°C (-328°F to +302°F)
Accuracy: ±0.2°C (±0.4°F) at 25°C (77°F)
Response Time: (to reach 90%) In water, with stirring: <10sec
Display Resolution: 0.1°C (0.1°F)
Optional DI (Digital Input): dry contact available
Door Contact
Circuit type Open loop
Operation gap ½”(13mm)
Color: White
Terminals: Screw-type
Mounting Tabs: Yes
Case: High-impact ABS plastic
Contacts: Deactivated rhodium on gold under-plating
Contact rating: 0.1A@100VDC (max) 1.0A@10VDC (max) 10W (max)
Temperature: -15°~160°F (-25°~70°C)
Switch cycles: 50 Million (0.1mA@5VDC)
Switch Dimensions: 21/2′′x9/16′′x1/2′′ (63.5x14x13mm)
Magnet Dimensions: 21/2′′x1/2′′x1/2′′ (63.5x13x13mm)
Magnet Type: Ferrite
Output: I2C
Pneumatic Connection: Manifold or Tube
Pressure range (bidirectional): 125 Pa 0.5” H2O
Accuracy of measured value: 3%
Lowest detectable pressure: < 0.01 Pa
Measurement speed: 0.5 ms
Calibrated for: Air, N2
Gas compatibility: Air, inert gases
[maxbutton id="1" ]
Aegis provides affordable, low power Wi-Fi sensor network solutions that make a ubiquitous sensing world come alive and a full line of controlled temperature cabinets. Laboratory, Pharmacy and Chromatography refrigerators and freezers which are designed to meet the dimensional and temperature requirements of the scientific community.
OH: 513 204 5837
PA: 215-281-9180
support@aegisfridge.com