General Specifications | |
Cabinet Type | Upright |
Capacity | 218L / 7.69 CuFt |
Internal Size(W*D*H) | 470*580*767mm 18.5*22.8*30.1in |
External Size(W*D*H) | 840*985*1568mm 33.0*38.7*61.7in |
Package Size(W*D*H) | 1098*988*1761mm 43.2*38.8*69.3in |
NW/GW(Kgs) | 218/235 |
Performance | |
Temperature Range | -40 ~ -86 °C |
Ambient Temperature | 16 – 32°C |
Climate Class | N |
Cooling Performance | -86 °C |
Controller | Microprocessor |
Display | Digital display |
Refrigeration | |
Compressor | 1 |
Cooling Method | Direct cooling |
Defrost Mode | Manual |
Refrigerant | Mixture gas |
Insulation Thickness(mm) | 155 |
Construction | |
External Material | Steel plates with spraying |
Inner Material | Galvanized steel sheet |
Shelves | 1 (Stainless steel) |
Door Lock with Key | Yes |
External Lock | Yes |
Access Port | 1 |
Casters | 4 |
Data Logging/Interval/Recording Time | Printer/Record every 20 minute / 7 days |
Backup Battery | Yes |
Alarm | |
Temperature | High/Low temperature,High ambient temperature |
Electrical | Power failure , Low battery |
System | Sensor error, System failure, Condenser cooling failure,Door ajar |
Electrical | |
Power Supply(V/HZ) | 110/60 |
Power(W) | 900 |
Rated Current(A) | 7.9 |
Options Accessory | |
System | Chart recorder, CO2 backup system |
Uses your existing WiFi network to monitor across all your facilities. Automates monitoring of temperature, humidity, differential pressure, CO2 and more to meet compliance standards with 24/7 real-time continuous monitoring. Alerting system uses emails, text messages and APPs for notifications. The system meets 21 CFR 11 requirements, are ideal for monitoring of refrigerators, freezers and ultralow freezers.
[maxbutton id="1" url="https://www.aegisfridge.com/contact/" ]Uses the cell phone network to monitor across all your facilities thereby eliminating IT security concerns, network performance issues and support commitment from IT. Automates monitoring of temperature, humidity, differential pressure, CO2 and more to meet compliance standards with 24/7 real-time continuous monitoring. Alerting system uses emails, text messages and APPs for notifications. The system meets 21 CFR 11 requirements, are ideal for monitoring of refrigerators, freezers and ultralow freezers.
[maxbutton id="1" url="https://www.aegisfridge.com/contact/" ]Sentinel Next PRO Probe for ultra-low freezers and liquid nitrogen chambers. Used in tissue and blood storage, pharmaceutical and other healthcare applications
Probe Length & Diameter Stainless probe: 25mm, Ø 4mm (1”, Ø 0.16”)
Cable Length: 304cm (10ft)
Measurement Range: -30°C to +150°C (-22°F to +302°F)
Accuracy: ±0.2°C (±0.4°F) at 25°C (77°F)
Response Time (to reach 90%) In water, with stirring: <10sec
Display Resolution: 0.1°C (0.1°F)
![]() |
Air Cooling, Auto defrost Better cabinet temperature uniformity, Auto defrost |
![]() |
Adjustable Shelves The shelves are adjustable to any height and satify different requirements. |
![]() |
Five Alarm Functions High/low temperature, Power failure, Door ajar, Sensor error , Low battery |
Key Features
Sentinel Next Temperature and Relative Humidity Connector
Temperature Measurement Range: -40°C to +125°C (-40°F to +257°F)
Accuracy: ±0.3°C (±0.5°F)
Relative Humidity Range: 0 to +100% RH
Response Time: (to reach 66%) 5 to 30sec for T; 8sec for RH
Display Resolution: 0.1°C (0.1°F)
Sentinel Next RTD probe with Dry Contact for ultra-low freezers and liquid nitrogen chambers. Used in tissue and blood storage, pharmaceutical and other healthcare applications
Probe Length & Diameter Stainless probe: 25mm, Ø 4mm (1”, Ø 0.16”)
Cable Length: 183cm (6ft)
Measurement Range: -200°C to +150°C (-328°F to +302°F)
Accuracy: ±0.2°C (±0.4°F) at 25°C (77°F)
Response Time: (to reach 90%) In water, with stirring: <10sec
Display Resolution: 0.1°C (0.1°F)
Optional DI (Digital Input): dry contact available
Door Contact
Circuit type Open loop
Operation gap ½”(13mm)
Color: White
Terminals: Screw-type
Mounting Tabs: Yes
Case: High-impact ABS plastic
Contacts: Deactivated rhodium on gold under-plating
Contact rating: 0.1A@100VDC (max) 1.0A@10VDC (max) 10W (max)
Temperature: -15°~160°F (-25°~70°C)
Switch cycles: 50 Million (0.1mA@5VDC)
Switch Dimensions: 21/2′′x9/16′′x1/2′′ (63.5x14x13mm)
Magnet Dimensions: 21/2′′x1/2′′x1/2′′ (63.5x13x13mm)
Magnet Type: Ferrite
Aegis provides affordable, low power Wi-Fi sensor network solutions that make a ubiquitous sensing world come alive and a full line of controlled temperature cabinets. Laboratory, Pharmacy and Chromatography refrigerators and freezers which are designed to meet the dimensional and temperature requirements of the scientific community.
OH: 513 204 5837
PA: 215-281-9180
support@aegisfridge.com